5.7 Host Channel NCQ Setting
The RAIDBank4 supports Native Command Queuing (NCQ) over the eSATA host connection.
The NCQ algorithms allow I/O operations to be performed out of order to optimize performance.
Since different host bus adapters have some compatibility differences in NCQ implementation,
The default setting on this option is Disable for better compatibility. To enable NCQ, choose
the option that matches your eSATA host bus adapter:
•ESB2/MACPro/Siliconlimage:IntelESB2,MACPro,MicroNet,andSiliconImagebasedadapters
•ICH:IntelICHseriesbasedadapters
•Marvell6145:Marvell6145basedadapters
•nVidia:NvidianForcebasedadapters
5.8 HDD Read Ahead Cache
Enabled by default. Please do not change this setting unless instructed by MicroNet’s Technical Support.
5.9 Staggered HDD Spinup control
The RAIDBank4 employs a staggered disk mechanism startup sequence to minimize power supply
strain. Please do not change this setting unless instructed by MicroNet’s Technical Support.
5.10 HDD Idle Spindown Control
The RAIDBank4 can automatically spin down disks that haven’t been accessed for a certain
amount of time to reduce power consumption. This value is used to determine idle time
before spinning down the disk(s).
5.11 Empty tray LED Control
(ON or OFF) If this option is selected, the disk error LED will light on a slot without a disk.
5.12 HDD SMART Status Polling
The RAIDBank4 reads and reports the SMART (Self-Monitoring, Analysis, and Reporting Technology)
status of each disk drive mechanism. This option is enabled by default, and should not be disabled
unless instructed by MicroNet’s Technical Support.
5.13 Disk Capacity Truncation Mode
Disk Truncation is used to decrease disk usable space for compatibility purposes. Please do
not change this setting unless instructed by MicroNet’s Technical Support.
5.14 Serial Port Configuration
The RAIDBank4 has provisions for an RS232 host management connection. In order to use the
RS232, a special cable has to be used (not included)- consult your authorized Micronet reseller
for more information. To set or change the RAIDBank4 communications port configuration,
Scroll to the “Terminal Port Configuration selection and press ENT. The communications port
configuration defaults are 115200 Baud., 1 Stop bit operation. The baud rate (1200-115200)
and stop bits (1,2) are user selectable. Handshaking and parity are fixed at none.
5.15 Reset Controller
To reset the RAIDBank4, select “Reset Controller” and then
press ENT. Press ENT at the confirmation screen to reset
the controller.
IMPORTANT: Controller Reset
can only be performed if no host
or drive activity is present.
!
3-RAID Control-LCD
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 65 66

Comentarios a estos manuales

Sin comentarios

Basler-electric BE1-700 manuales

Manuales del propietario y guías del usuario para Relé Basler-electric BE1-700.
Ofrecemos 1 manuales en pdf Basler-electric BE1-700 para descargar gratis por tipos de documentos: Manual de usuario


Tabla de contenidos

INSTRUCTION MANUAL

1

BASLER ELECTRIC

4

12570 STATE ROUTE 143

4

HIGHLAND IL 62249-1074 USA

4

REVISION HISTORY

5

CONTENTS

9

TABLE OF CONTENTS

11

DESCRIPTION

13

FEATURES

13

OPERATIONAL SPECIFICATIONS

18

MEASURED

19

GENERAL SPECIFICATIONS

23

SECTION 2 • QUICK START

27

BESTLOGIC

30

USER INTERFACES

31

GETTING STARTED

34

FAQ/TROUBLESHOOTING

35

POWER SYSTEM INPUTS

41

CONTACT-SENSING INPUTS

44

OUTPUTS

47

P0055-47

48

SETTING GROUPS

57

P0002-22

62

09-08-03

62

Phase-Phase

76

Measured

76

Volt/Hz Characteristic

80

D2871-21

85

05/13/02

85

D2881-29

89

08-12-04

89

LOGIC TIMERS

99

D2843-12

101

10-23-03

101

D2863-07

101

RECLOSING (OPTIONAL)

104

SYNC-CHECK PROTECTION

112

VIRTUAL SWITCHES

118

SECTION 5 • METERING

125

FUNCTIONS

131

GENERAL STATUS REPORTING

135

DEMAND FUNCTIONS (BE1-700C)

137

BREAKER MONITORING

139

D2849-09.vsd

142

05-26-99

142

TRIP CIRCUIT MONITOR

146

FAULT REPORTING

148

SEQUENCE OF EVENTS RECORDER

158

ALARMS FUNCTION

159

RA-MAJ=0

163

RA-MIN=0

163

HMI RESET KEY

163

SETTINGS COMPARE

165

INTRODUCTION

169

1-at least 1 of 3

170

2-at least 2 of 3

170

3-all 3 of 3 phases

170

(OPTIONAL)

171

0 - Disable

172

1 - Discrete Input

172

2 - Binary Input

172

EQUATI ON

174

D2861-16

174

08-21-03

174

LOGIC SCHEMES

176

BESTlogic™ APPLICATION TIPS

179

SECTION 8 • APPLICATION

181

BE1-700C

187

Input 0 Logic:

188

Input 1 Logic:

188

Auto/Manual Logic:

188

P0014-115

201

06-11-04

201

(BE1-700V)

205

APPLICATION TIPS

213

D2881-42

214

10-05-04

214

SECTION 9 • SECURITY

225

FRONT PANEL DISPLAY

233

5 PROTECTION

239

700XXX-5051-A-BE

239

HMI OPERATIONS

242

SERIAL PORT

247

ASCII COMMAND INTERFACE

247

COMMAND SUMMARY

255

SECTION 12 • INSTALLATION

269

RELAY CONNECTIONS

273

ETHERNET

278

D2838-47

279

06-04-04

279

POWER SYSTEM APPLICATIONS

282

SETTINGS

288

COMMUNICATIONS CONNECTIONS

288

D2848-46

289

02/11/04

289

GENERAL

297

TESTING PHILOSOPHIES

297

ACCEPTANCE TESTING

299

COMMISSIONING TESTING

304

PERIODIC TESTING

308

CARE AND HANDLING

309

STORAGE

309

FUNCTIONAL TESTING

310

INSTALLATION

356

UPDATING BESTCOMS™ SOFTWARE

357

STARTING BESTCOMS™

357

CONFIGURING THE PC

358

SETTING THE RELAY

358

METERING

386

FILE MANAGEMENT

387

BESTprint™

389

CONFIGURATION SCREENS

395

VIEWING WEB PAGES

404

E-MAIL ALERTS

409

TCP/IP ASCII COMMUNICATION

411

ETHERNET PORTS

413

UNIQUE ASCII COMMANDS

413

TROUBLESHOOTING GUIDE

413

CHARACTERISTIC CURVES

415

THE 46 CURVE

420

Setting Pickup46

421

IMeasured

421

Table B-4. Report Commands

442

Table B-5. Setting Command

442

TIME CURVES

453

CURVE SPECIFICATIONS

455

Trip Time in Seconds

456

D1089-15

457

03-03-04

457

D1089-17

458





Más productos y manuales para Relé Basler-electric

Modelos Tipo de documento
BE1-50/51B-219 Manual de usuario   Basler Electric BE1-50/51B-219 User Manual, 52 paginas
BE1-50/51B-235 Manual de usuario   Basler Electric BE1-50/51B-235 User Manual, 68 paginas
BE1-50/51B-230 Manual de usuario   Basler Electric BE1-50/51B-230 User Manual, 76 paginas
BE1-50/51B-237 Manual de usuario   Basler Electric BE1-50/51B-237 User Manual, 70 paginas
BE1-51 Manual de usuario   Basler Electric BE1-51 User Manual, 100 paginas
BE1-64F Manual de usuario   Basler Electric BE1-64F Manual del usuario, 28 paginas
BE1-64F Manual de usuario   Инструкция по эксплуатации Basler Electric BE1-64F, 28 paginas
BE1-64F Manual de usuario   Basler Electric BE1-64F User Manual, 30 paginas
BE1-51/27C Manual de usuario   Basler Electric BE1-51/27C User Manual, 112 paginas
BE1-25 Manual de usuario   Basler Electric BE1-25 User Manual, 66 paginas
BE1-51/27R Manual de usuario   Basler Electric BE1-51/27R User Manual, 114 paginas
BE1-87G Manual de usuario   Basler Electric BE1-87G User Manual, 68 paginas
BE1-59N Manual de usuario   Basler Electric BE1-59N User Manual, 40 paginas
BE3-25 Manual de usuario   Basler Electric BE3-25 User Manual, 2 paginas
BE3-25 Manual de usuario   Инструкция по эксплуатации Basler Electric BE3-25, 2 paginas
BE3-27T Manual de usuario   Basler Electric BE3-27T User Manual, 2 paginas
BE3-27 Manual de usuario   Basler Electric BE3-27 User Manual, 2 paginas
BE3-32 Manual de usuario   Basler Electric BE3-32 User Manual, 2 paginas
BE1-32R Manual de usuario   Basler Electric BE1-32R User Manual, 82 paginas
BE3-27T Manual de usuario   Инструкция по эксплуатации Basler Electric BE3-27T, 4 paginas